Shop is live

We build Workstation AI machines for websites, AI agents, and LLM training — configure and buy online.

Enter the shop
AI Products
AI LabsOpenAI AgentsClaude AgentsGrok BotWorkstation AI native CRMMarketingAll Products
AI Solutions
Applied AIAI AgentsGenerative AIAI AutomationAI UpskillingAI SME PackagesEnterprise AI LabAI WorkstationsNVIDIA Hardware & SoftwarePrivate AIGPU ClustersEdge AIAI by Industry
AI Services
Platform ModernisationDigital EngineeringData Foundations & AIAutonomous OperationsAI ConsultancyDevOps AutomationCyber SecuritySoftware DevelopmentAgent BuildingMLOps Setup
About Us
Our StoryPartnersCustomer Stories
AI InsightsJev seriesBenchmark LabModel selection
Articles
Documentation
ToolsWSL ProxyRing PromoterWSL VaultJobshoutSysOps 24/7
News
Blog
Contact UsSign in

AI workstations, AI Multi Agentic Software, GPU infrastructure, and intelligent agent solutions for modern businesses.

Contact Us

AI Solutions

Applied AIAI AgentsGenerative AIAI AutomationAI UpskillingAI SME PackagesEnterprise AI LabAI by Industry

Products

All ProductsWorkstation AI native CRM & ERPMarketingOpenAI AgentsWSL ProxyRing PromoterWSL VaultJobshoutSysOps 24/7

Company

About UsWhy WorkstationPartnersCustomer StoriesPricingContactTenthMatrix

Resources

AI InsightsArticlesDocumentationBlogSearchSitemap
UK Office
77-79 Marlowes, Hemel Hempstead HP1 1LFDirections - Take Junction 20 off M25 Outer LondonCompany No: 11641870Mon - Fri: 9:00 AM - 6:00 PM GMT
+44 7515 356 146
Belgium Office
Workstation SRL, Rue Vanderkindere 34, 1180 Uccle, BrusselsBE 0751.518.683Mon - Fri: 9:00 AM - 6:00 PM CET
+32 492 45 67 46
India Office
#159 Sector 9, Pocket 1, DDA Flats, 110077 Dwarka, New Delhi
+91 98881 98841

© 2026 Workstation AI. All rights reserved.

PrivacyData DeletionCookiesTerms of ServiceWebsite Sitemap

Grace Blackwell Ultra · 72 GPUs · one NVLink domain

GB300 NVL72 rack-scale system

72 Blackwell Ultra GPUs and 36 Grace CPUs joined into a single liquid-cooled NVLink domain: one rack that behaves like one enormous GPU.

Rack-scale systems in the shopPlan an AI factory with us
  1. AI factories
  2. GB300 NVL72 rack-scale system

In an ordinary GPU server, eight GPUs share fast NVLink and everything else talks over the network. GB300 NVL72 removes that boundary. Its NVLink Switch spine joins all 72 Blackwell Ultra GPUs in the rack into one domain with 130 TB/s of bandwidth, so a model can be spread across the whole rack as if it were a single accelerator.

That matters most for the hardest AI work: very large mixture-of-experts models, long-context reasoning and serving thousands of users at low latency. NVIDIA quotes up to 10 times better responsiveness per user and 5 times more throughput per megawatt than Hopper, adding up to a 50-fold increase in AI factory output.

It is also a facilities project. The rack is fully liquid cooled and draws well over 100 kW, so the hall, the coolant loop and the power feeds have to be ready before it arrives. Planning that is where we start.

Who it suits

  • Organisations serving frontier-size or mixture-of-experts models to many users
  • AI labs training very large models where communication is the bottleneck
  • National, sovereign and research AI programmes building multi-rack capacity
  • GPU service providers offering premium, low-latency inference
72
Blackwell Ultra GPUs in one NVLink domain
20 TB
HBM3e (37 TB fast memory in total)
130 TB/s
NVLink bandwidth
1,440 PF
FP4 (1,080 PF dense)

What it does for you

One rack, one giant GPU

Every GPU can reach every other at full NVLink speed. Tensor and expert parallelism stay inside the rack instead of crossing the network, which is where large models usually lose time.

Fast answers for many users at once

With 2 times the attention performance of Blackwell and 1.5 times the dense FP4 throughput, GB300 is built for reasoning models that generate long chains of thought for every request.

37 TB of fast memory

20 TB of HBM3e on the GPUs plus 17 TB of LPDDR5X on the Grace CPUs, coherently connected, so huge key-value caches and models stay in memory.

Liquid cooling, done properly

We plan the coolant distribution unit, secondary loop, water quality, leak detection and maintenance regime with your facility team, not around them.

Reference configuration

NVIDIA's published figures for the rack.

Configuration72 NVIDIA Blackwell Ultra GPUs, 36 NVIDIA Grace CPUs (2,592 Arm Neoverse V2 cores)
GPU memory20 TB HBM3e, up to 576 TB/s
CPU memory17 TB LPDDR5X, 14 TB/s
NVLink130 TB/s across the rack
FP4 Tensor Core1,440 | 1,080 PFLOPS
FP8 / FP16 Tensor Core720 / 360 PFLOPS (sparse)
NetworkingConnectX-8 SuperNICs, 800 Gb/s per GPU, on Quantum-X800 InfiniBand or Spectrum-X Ethernet
CoolingFully liquid cooled, rack-scale
SoftwareNVIDIA AI Enterprise, Dynamo and NIM for inference, Mission Control for operations

Figures are NVIDIA's published specifications for the platform. Where NVIDIA quotes two Tensor Core figures, the first assumes sparsity and the second is dense. The exact build (CPUs, memory, storage, cooling, networking) is agreed with you and confirmed on a written quote.

Facility check before anything is ordered

GB300 NVL72 is a data-centre engineering project. These are the questions we answer with you first.

PowerWell over 100 kW per rack; we confirm the exact figure for your configuration
CoolingDirect liquid cooling with a coolant distribution unit and facility water supply
FloorA fully populated rack weighs well over a tonne: floor loading and access routes are checked
NetworkSpine capacity for 72 × 800 Gb/s per rack, plus storage and management networks
HostingFew UK halls can take this density today; we can shortlist colocation sites that can

Choose it when

  • One model or one serving instance needs far more than 8 GPUs at NVLink speed
  • Latency per user matters as much as total throughput
  • You have, or can get, liquid-cooled space with over 100 kW per rack

Look at something else when

  • Your hall is air-cooled or limited to around 60 kW per rack: HGX B300 delivers Blackwell Ultra in a standard rack
  • You need strong FP64 for simulation: GB200 NVL72 keeps it

How we deliver it

One accountable UK team from sizing to day-two operations

Facility design

Power, cooling loop, floor and fibre designed with your facilities team or colocation provider.

Logistics and installation

Rack-level delivery, positioning, coolant commissioning and power-on, with the vendor where required.

Rack validation

NVLink, fabric and thermal acceptance tests before production workloads.

Day-two operations

Mission Control, monitoring, firmware life cycle and SysOps247 cover once it is live.

Supply, lead times and export controls

NVIDIA data-centre GPUs are allocated by NVIDIA and the server makers, and lead times are measured in months rather than weeks. Complete, tested systems usually get allocation sooner than loose parts, so we quote these platforms as built systems. Shipments outside the UK, and many advanced GPUs within it, need an end-user and end-use check under UK and US export rules before we can confirm supply.

Trade membership

Trade members get our engineers' time on sourcing and design questions, early stock and waitlist priority, and free technical support on every order.

Explore Trade membership

Frequently asked questions

Is GB300 NVL72 a single computer?

It is 18 compute trays and 9 NVLink switch trays in one rack. To your software, the 72 GPUs form one NVLink domain, so frameworks can treat the rack as one very large accelerator.

Can we put it in our existing server room?

Only if the room can supply well over 100 kW to one rack and has liquid-cooling infrastructure. Most customers place it in a specialist colocation hall. Our site survey settles the question early.

How is it different from DGX GB300?

DGX GB300 is NVIDIA's own version of the rack with NVIDIA's software and support package. Partner GB300 NVL72 systems use the same architecture from other server makers. We can supply either and explain the trade-offs.

Related reading on our site

GB200 NVL72DGX SuperPODVera Rubin NVL72

Thinking about an AI factory?

Tell us what you want it to produce, how many people will use it and where it would live. An engineer will come back with a sized recommendation and an honest view on whether owning makes sense for you.

Rack-scale systems in the shopPlan an AI factory with us

Other AI factory solutions

All AI factory solutions

HGX B300 32-GPU AI factory rack

Blackwell Ultra · 4 nodes · 32 GPUs

Four 8-GPU Blackwell Ultra servers, an 800 Gb/s fabric and fast storage in one tested rack: the most practical way to put serious reasoning and training capacity into a standard data hall.

View solution

HGX B200 AI and HPC cluster

Blackwell · 8 GPUs per node · full FP64

8-GPU Blackwell servers that are equally at home training models and running double-precision science, built into clusters of one to 32 nodes.

View solution

GB200 NVL72 rack-scale system

Grace Blackwell · 72 GPUs · liquid cooled

The first rack-scale Grace Blackwell system: 72 GPUs in one NVLink domain for trillion-parameter models, with strong double precision for science.

View solution

NVIDIA DGX SuperPOD

DGX B300 or DGX GB300 · scalable units · Mission Control

NVIDIA's validated, turnkey AI supercomputer, built from DGX B300 or DGX GB300 systems in standard scalable units and run with Mission Control.

View solution

RTX PRO 6000 enterprise AI factory

Blackwell · air cooled · 8 GPUs per server

Air-cooled servers with eight RTX PRO 6000 Blackwell Server Edition GPUs each: the most accessible AI factory for enterprise agents, visual computing and physical AI.

View solution

H200 NVL inference servers

Hopper · PCIe · 141 GB HBM3e

PCIe Hopper GPUs with 141 GB of HBM3e each, bridged in groups of two or four: high-memory inference that drops into existing air-cooled racks.

View solution

Vera Rubin NVL72: planning the next generation

Rubin · HBM4 · NVLink 6

72 Rubin GPUs with HBM4 and 36 Vera CPUs in one liquid-cooled rack. If you are building capacity for 2027 and beyond, the facility decisions start now.

View solution

AI factory networking

800 Gb/s per GPU today · 1.6 Tb/s next

Quantum InfiniBand or Spectrum-X Ethernet, SuperNICs, DPUs and cabling: the fabric that decides whether your GPUs work as one machine.

View solution

Compal SGX30-2 HGX B300 server

NVIDIA-Certified · 10U · air cooled · available to order

An NVIDIA-Certified, air-cooled 10U server with eight Blackwell Ultra GPUs, 3 TB of DDR5 and an 800G port per GPU: our standard building block for an HGX B300 AI factory.

View solution